How to Troubleshoot Your Reverse Osmosis System

Posted By

John Woodard on July 27, 2018
Updated on November 17, 2026

How to Troubleshoot Your Reverse Osmosis System

Reverse osmosis systems are one of the best water treatment systems available to homeowners, but like any equipment, they need routine care and occasionally run into problems. This guide covers both: the simple maintenance that keeps your RO system producing clean, great-tasting water, and step-by-step fixes for the most common reverse osmosis problems when something goes wrong.

Quick answer: To maintain an RO system, replace the sediment and carbon prefilters every 6 to 12 months, the postfilter about once a year, and the membrane every 2 to 5 years. Check the tank's air pressure (about 7 to 8 psi when empty) and sanitize the system once a year. Most RO problems trace back to a few parts: slow water usually means clogged prefilters or low tank pressure, nonstop drain flow points to the ASO valve, check valve, or flow restrictor, and leaks almost always come from O-rings or tubing not pushed fully into a fitting.

Time for new filters? Shop RO replacement filter kits and RO membranes, or upgrade with a new reverse osmosis system.

RO Maintenance Schedule

Task How often
Replace sediment and carbon prefilters Every 6–12 months
Replace carbon postfilter About every 12 months
Replace RO membrane Every 2–5 years, or when TDS rejection drops
Check tank air pressure At every filter change
Sanitize system and tank Once a year
Test TDS Every few months

Water usage, chlorine levels, hardness, and overall feed water quality can all affect replacement timing. When available, always follow your manufacturer's recommended schedule.

Key Components of an RO System

Knowing the parts of your reverse osmosis system makes both maintenance and troubleshooting much easier.

  • Filters: Prefilters provide sediment and chlorine protection. Sediment can damage or clog the flow restrictor. Chlorine can destroy the membrane material by oxidation. Postfilters provide a fresh pass through carbon on the way to your faucet, ice maker, or refrigerator.
  • Membrane: The RO membrane operates on pressure, which is the driving force that pushes water through the system. Without adequate driving force pressure, water production and TDS rejection will be negligible. Production rate varies based on feed pressure and water temperature.
  • Flow restrictor: The flow restrictor provides resistance to create driving force on the RO membrane while efficiently metering water flow rate to the drain. It's sized according to the membrane output rating and disrupts membrane output if not correct.
  • Check valve: The check valve is placed at the membrane permeate (filtered water) outlet. It protects the membrane from back pressure and allows pressure to build with the tank filled, activating the ASO valve. Without it, the RO system will not shut down and could potentially cause membrane failure due to backflow.
  • ASO (automatic shut-off) valve: This device monitors feed and tank pressures. When tank pressure reaches 2/3 of line pressure, the ASO valve hydraulically closes, stopping water flow.
  • Storage tank: RO storage tanks are pressure (hydro-pneumatic) tanks divided into two chambers, one for water and one for air. As the tank fills with water, the separating diaphragm expands into the air side and increases the pressure on that side. This pressure pushes the water back out of the tank to the faucet or another point of use. Loss of pre-charge air pressure or diaphragm integrity can cause little or no flow at the faucet.
  • Drain saddle: RO systems have a flow to the drain that carries contaminants away. The drain line connects to the sink drainpipe with a drain saddle.
  • Air gap: Plumbing codes require any cross connection (feed supply on one side, drain connection on the other) to have backflow prevention to prevent drain or sewage water from backing up into the drinking water supply.
  • Feed pressure: The water pressure entering the RO system is crucial to the system's performance. High levels of TDS and low pressure can both reduce performance.

How a Reverse Osmosis System Works

How to Maintain a Reverse Osmosis System

Most homeowners only need to perform a few core maintenance tasks each year, but staying on schedule protects the membrane, keeps water tasting fresh, and lowers long-term ownership costs.

Replace RO Prefilters

  • Replace every 6–12 months
  • Protect the membrane from chlorine and sediment
  • May need earlier replacement with high sediment or chlorine levels

Signs replacement may be needed: reduced flow rate, visible sediment loading, or increased pressure drop. If carbon filters become exhausted, chlorine can reach the membrane and permanently damage it, leading to premature membrane replacement.

Replace the RO Postfilter

  • Replace about every 12 months
  • Acts as a final polishing stage to improve taste and odor before water reaches the faucet

Signs replacement may be needed: unpleasant taste or odor returning to your drinking water.

4-stage RO system

Shop RO replacement filter kits to get every prefilter and postfilter in one order.

Replace the RO Membrane

  • Replace every 2–5 years
  • Hard feed water, especially without a water softener, can scale the membrane and shorten its life
  • Soft-water applications may allow longer membrane life

Signs replacement may be needed: rising TDS readings, reduced contaminant rejection, or slower water production. Browse residential RO membranes.

Check Your Membrane With a TDS Meter

A handheld TDS meter is one of the easiest and most affordable tools for monitoring RO performance. It measures dissolved minerals and salts in parts per million (ppm). It does not identify specific contaminants, but it shows how well the membrane is working.

How to check your membrane with a TDS meter:

  1. Measure the TDS of your tap water.
  2. Measure the TDS of water from your RO faucet.
  3. Calculate the rejection rate: (tap TDS − RO TDS) ÷ tap TDS × 100.
  4. Most membranes reject about 90% or more when new. If it drops below about 80%, it's usually time to replace the membrane.

For example, if your tap water is 300 ppm and your RO water is 20 ppm, your rejection rate is about 93%.

Check RO Tank Pressure

RO storage tanks rely on an internal air bladder to push water to the faucet. Check the pressure at every filter change, or sooner if you notice very slow flow, little stored water, or short bursts of water followed by trickling.

  1. Shut off the feed water.
  2. Open the faucet and completely drain the tank.
  3. Measure air pressure at the air valve (Schrader valve) with a low-pressure gauge.
  4. Adjust to the manufacturer's specification, typically 7–8 psi for most residential tanks.

Note: Always check pressure with the tank completely empty.

Drain the RO Storage Tank

When water sits in the tank for long periods, especially in low-usage homes, freshness can decline. Fully drain the RO storage tank periodically so the system refills with fresh water, and drain it more often if you notice an unusual taste or odor.

Practical tip: Drain the storage tank before you head to bed so the system can refill overnight and be ready in the morning.

How to Sanitize a Reverse Osmosis System

Sanitize your RO system at least once a year to control bacterial growth inside filter housings, tubing, and the storage tank. It's easiest to do during a scheduled filter change, since the system is already open.

How to Sanitize a Traditional RO System

Caution: Shut off the water supply and completely drain the system before beginning.

  1. Turn off the feed water supply.
  2. Drain the storage tank completely.
  3. Remove all prefilters, postfilters, and the membrane.
  4. Clean and inspect the filter housings.
  5. Add the approved sanitizer according to manufacturer instructions.
  6. Reassemble the empty system.
  7. Allow the sanitizer to circulate and remain in contact for the recommended time.
  8. Flush the system thoroughly.
  9. Install new filters and membrane if scheduled.
  10. Complete all manufacturer-recommended flush cycles before use.

How to Sanitize the Tank on Quick-Change Systems

Quick-change RO systems use self-contained cartridges, so only the tank and tubing are sanitized.

  1. Shut off the water supply.
  2. Drain the storage tank completely.
  3. Add the approved sanitizer according to manufacturer instructions.
  4. Allow the tank to refill.
  5. Drain the tank completely.
  6. Repeat fill-and-flush cycles as recommended until all sanitizer has been removed.

Exact procedures may vary by sanitizer and system design.

RO Troubleshooting: Quick Diagnosis

Problem Most likely cause First thing to check
No or slow water Clogged prefilters, low feed pressure, low tank pressure Tank air pressure and prefilters
Runs to the drain nonstop ASO valve, check valve or flow restrictor Close the tank valve and see if drain flow stops
Loud gurgling Too much drain flow or saddle placement Drain flow rate test
Bad taste or odor Old filters, needs sanitizing, failing membrane Filter dates and TDS reading
Housing leak O-ring O-ring seating and condition
Fitting leak Tubing not fully inserted, cut crooked or scratched Re-cut and reinsert the tubing
Water from air gap faucet Kinked or long drain line, clogged drain saddle Straighten and shorten the drain tubing

How to Fix Common Reverse Osmosis System Problems

The most common RO system problems include lack of water, leaks, strange noises, or changes in water quality. Because the parts of an RO system work together, one symptom can have more than one cause, so work through these checks systematically.

1. RO Storage Tank Problems

Check the tank to see if it is full of water. If it is full, open the faucet and check the flow rate. If nothing is flowing, make sure the tank valve is in the open position (handle in line with the tubing). If everything looks right, check for pressure in the tank with a tire pressure gauge. If there is none, add pressure with a bicycle pump with the faucet open until the tank empties. Once the tank is empty, set the air pressure to the tank's rating, usually about 7 to 8 psi. If water spurts out when checking for pressure, the tank's diaphragm has failed and the tank should be replaced.

If the tank is full and pressure exceeds 20-25 psi, with no water to the faucet, make sure the tank is functioning. First, turn off the tank valve, then disconnect the tank tube from the RO system and see if water flows into a bucket when the valve is on. If so, check the postfilter to make sure it's not clogged.

2. No, Slow, or Very Little Water

If your RO system is outputting slowly or not at all, check the following:

  1. Permeate flow rate: Close the tank valve, and then open the faucet handle. After a steady drip begins, measure the output for 60 seconds.
  2. Drain flow rate: Disconnect the tubing where it hooks to the drain line. Let it run into a large measuring cup for 30 seconds.
  3. Feed pressure: Recording your feed pressure helps, but may not always be possible. Most RO systems need about 50 psi to work well. If your pressure is low, an RO booster pump can help.
  4. Tank pressure: A simple tire gauge applied to the air valve under the blue cap on the side of the tank gives a close reading. With the tank empty, it should usually read about 7 to 8 psi.
  5. Improper hook up: Compare your setup with installation diagrams that show the feed and drain connections.

Learn more: How to install a reverse osmosis system

3. Constant Run to the Drain

The reverse osmosis system shuts down when tank pressure reaches 2/3 of supply line pressure and the ASO valve closes. Constant water running to the drain means the ASO is not shutting off. The ASO operates only if the membrane, flow restrictor, tank, and check valve are all performing properly. You can test this quickly by turning the tank valve off to see if the ASO stops flow to the drain. This may take a few minutes depending on membrane output.

Possible causes:

  • Flow restrictor is missing or failed. A drain flow rate test will show a large amount of water to the drain, usually with lots of noise.
  • Tank is not filling enough to build the needed pressure. A flow rate test should identify if there is a membrane production issue.
  • ASO valve is stuck. Completely disconnect the valve to make sure all pressure is off the assembly.
  • Check valve is bleeding pressure, preventing the system from reaching shut-off pressure. Test this with a full tank of water while the tank valve is open. Turn the water supply off. If water still flows to the drain, the check valve is bleeding pressure. This failure is unusual, but still important to look for.

Reverse osmosis system noise

4. Noisy Gurgle

Loud, noisy water running to the drain is typically the result of too much water going to the drain. Use the drain flow rate test to identify this problem. The location of the drain saddle could be another contributor.

Locating the saddle on the crossover pipe is best for noise reduction, since a pipe directly under the sink may amplify sound. However, an RO system will always make some noise while it runs.

5. Bad Taste or Odor

Taste and odor problems usually mean the filters need changing, the tank and system need sanitizing, or the membrane has failed from high TDS breakthrough. Start with the maintenance schedule above.

Well water that contains dissolved gas, like hydrogen sulfide or methane (rotten egg smell), will concentrate and enhance the odor. You may not know you have a hydrogen sulfide issue until it concentrates through the membrane. On-board carbon filtration will not hold gases for long, so you may not detect an odor in a new system for several days. These issues must be corrected before installing a new reverse osmosis system.

6. Fitting or Housing Leaks

Housing leaks are almost always O-ring related. Either the O-ring is not seated where it should be, or it has been compromised. Reused O-rings may stretch when removing the housing to change filters. It's always a good idea to have an extra set of O-rings and some food-grade silicone O-ring lubricant on hand.

Why a fitting may leak:

  • Tubing is not pushed fully into the fitting. Small tubes, such as 1/4" and 3/8", insert about 5/8" to 3/4" into a push-to-connect fitting. Mark the tubing at the insertion depth for your fitting and make sure the mark disappears when the tubing is pushed in.
  • Tubing was not cut straight, so it did not pass through the internal O-ring for a proper seal.
  • A deep scratch on the tubing is letting water pass. Each time tubing is inserted and released, it gets scratched. Replace any worn or scratched tubing that inserts into a fitting.

Shop replacement RO tubing and John Guest fittings.

7. Leaks From the Air Gap Faucet

These leaks are common in newly installed RO systems. The air gap faucet sends drain water through a backflow prevention gap on its way to the drain, and the water flows to the drain by gravity alone. Leaving too much tubing on this connection is the most common installation error. If the tubing is not as straight as possible to the drain saddle, water will come out of the air gap hole in the base of the faucet.

air gap leak

A clogged drain line or drain saddle connection can also cause this, as debris collects in the base of the fitting over time. If all is clear, make sure the hole in the drainpipe lines up with the saddle fitting.

In rare instances, Tomlinson RO faucets can leak between the fixture's base and neck. First make sure the nut at the base of the neck is tightened. If water still leaks, unscrew the nut and pull the neck out of the base. The O-ring at the bottom of the neck is likely the cause. Replace it if it's damaged. If it looks normal, coat it with food-grade silicone lubricant and reassemble so the faucet sits all the way down in the base. Need a new faucet? Shop air gap RO faucets.

How to Test RO System Flow Rate

How to Test Permeate Flow Rate

The best way to check membrane function is by testing the permeate flow rate. Shut the tank valve off and open the faucet so membrane production flows directly to the faucet. Once the "fast drip" is consistent, collect it in a measuring cup for 60 seconds.

With normal feed pressure and water temperatures, the amount collected in 60 seconds should closely match the chart below.

Membrane Rating Permeate Rate (oz/min) Drain Flow Rate (ml/min / oz per min)
15 gpd 1-1.3 100-110/ 3.4-4
18 gpd 1.3-1.8 180/ 6
25 gpd 2 250/ 8.5
36 gpd 2.5-3 300/ 10
50 gpd 3-4 350-400/ 11-13.5
75 gpd 4.5-6 575-650/ 19-22
100 gpd 8-9 730-900/ 25-30
150 gpd 10-13 1200/ 40.5

How to Test Drain Flow Rate

To check whether you have the right amount of flow restriction, disconnect the drain line where it connects to the drain saddle. Point the open tube into a large measuring cup and collect water for 30 seconds. Multiply the result by two and compare it to the drain flow rate numbers in the chart above.

How to Interpret Results

  • Both results are within the acceptable range: The problem is not the pressure, membrane, or prefilters. The membrane has adequate pressure and flow and no clogs.
  • Both results are equally below the acceptable range: If your system's design allows, remove the prefilters from their housings and run the test again. If there's no change, you may have a pressure problem. If the flow rates return to normal, replace your prefilters.
  • The drain flow rate is close, but the permeate flow rate is next to nothing: The membrane may be scaled with hardness or fouled. It should be replaced, and additional pretreatment like a water softener may be needed. This could also indicate high TDS and low pressure, since the higher the TDS, the more pressure is needed.
  • The drain flow rate is too high, but the permeate flow is next to nothing: Check that the flow restrictor is in place. If the restrictor has failed, the membrane lacks driving pressure and will not produce water.
  • Both the drain and permeate flows are zero: Check the prefilters and make sure the water supply is on. Then turn the water off, disconnect the feed line at the system inlet, point it into a bucket, and turn the water back on to confirm the system is receiving water.

RO Maintenance and Troubleshooting FAQs

How often should I change my RO filters?

Replace the sediment and carbon prefilters every 6 to 12 months and the carbon postfilter about once a year. Replace the RO membrane every 2 to 5 years, or sooner if TDS rejection drops below about 80%. Hard water, high chlorine, and heavy use can all shorten filter life, so follow your manufacturer's schedule.

How often should I sanitize my RO system?

Sanitize your RO system at least once a year. The easiest time is during a scheduled filter change, since the housings are already open. Sanitizing controls bacterial growth in the housings, tubing, and storage tank. Always flush the system thoroughly afterward and follow your manufacturer's sanitizing instructions.

What should the air pressure be in an RO tank?

Most residential RO storage tanks should be set to about 7 to 8 psi when the tank is completely empty. Always drain the tank before checking. Use a low-pressure gauge on the air valve, and add air with a bicycle pump if it's low. Check the pressure at every filter change.

Why is my RO water coming out so slow?

The most common causes are clogged prefilters, low tank air pressure, low feed water pressure, or an aging membrane. Check the tank pressure with the tank empty first, since it's the quickest fix. If pressure is fine, replace the prefilters and run a permeate flow rate test to check the membrane.

Why does my RO system keep running to the drain?

Your system isn't shutting off. Usually the ASO valve, check valve, or flow restrictor has failed, or the tank isn't building enough pressure to trigger shut-off. To test, close the tank valve and wait a few minutes. If drain flow stops, the problem is likely the tank or check valve.

How do I know if my RO membrane is bad?

Test your tap water and RO water with a TDS meter. If the RO water's TDS keeps climbing, or the membrane is removing less than about 80% of the TDS, it's likely time to replace it. Slow production, even after new prefilters and correct tank pressure, is another common sign.

Why is water leaking from my RO air gap faucet?

Water usually leaks from an air gap faucet because the drain line is too long, kinked, or sloped, so water can't flow freely to the drain by gravity. Shorten and straighten the drain tubing to the drain saddle. If that doesn't fix it, check the drain saddle and line for clogs or misalignment.

Does reverse osmosis need maintenance?

Yes. Reverse osmosis systems need routine filter changes every 6 to 12 months, a new membrane every 2 to 5 years, periodic tank pressure checks, and annual sanitizing. Staying on schedule keeps your water clean and great tasting, protects the membrane, and helps the system last 10 years or more.

Final Tips for Maintaining and Troubleshooting Your RO System

Most RO problems can be prevented with consistency: replace filters and membranes on schedule, check tank pressure, drain the tank periodically, and sanitize once a year. When something does go wrong, the quick diagnosis table and flow rate tests above will help you find the cause fast.

Shop RO replacement filter kits, RO membranes, and RO storage tanks, or explore our full selection of reverse osmosis systems.

If you have any additional questions, please do not hesitate to contact us.

You may also like:

Comments


MIke Hobson

I replaced the tank and diaphragm and now I get a vibration and low hum. New filters. Went from a squeal to a hum after new diaphragm.


Josh Romero

Our RO system is supplying reject water to the storage tank but we aren’t getting any spot-free/purified water to our separate tank. Please help.


John Woodard, Master Water Specialist
Hello Bill!

Poor rejection can be created by a number of possibilities. Low pressure in the feed supply or a clogged prefilter can cause flow and pressure loss. New carbon filters will initially raise TDS until they are flushed out. TDS can raise if the automatic shut off valve (ASO) device is being by-passed or if the RO membrane has lost its integrity.

My first suggestion would be to isolate the membrane and examine the quality of water it is producing. Then turn off the tank valve and lift the faucet handle. The water should come out of the faucet as a fast drip. (For example, a 50 GPD membrane should give you 2-3 ounces in 60 seconds.) Let the water run for a few minutes then accumulate in a measuring cup to see if the flow rate of the water is correct, then test the water with your TDS meter.

If the flow rate is too fast then the membrane could be allowing the water to bypass. You then should check the ASO. Disconnect the tubing at the ASO device coming out of the membrane. Collect water directly from the membrane to see if flow rate and TDS are now where they should be.

It is also possible for new carbon filters to elevate the TDS levels. However, if you have flushed the tank several times, this should be rinsed out by this point.

Use a process of isolation and elimination to figure out where the problem may be occurring.

Hopefully, this helps. Let us know if you need additional information or guidance!


Bill
Hello, I have a older watts 5 stage r/o. Just replaced all filters, I’ve drained tank multiple times like always before use. Still getting high readings on TDS tester.. in the 200’s. never had this issue before.

John Woodard, Master Water Specialist

Hello Surendro!

Reverse osmosis membranes require flow to the drain to carry off dissolved inorganic minerals. Loss of this flow will eventually destroy or shut down the membrane. Loss of TDS rejection is the first symptom. First, try cleaning the drain line and specifically the flow restrictor to see if you can restore acceptable rejection

It is possible you will have to replace the flow restrictor and membrane to regain optimal performance.


Surendro
Waste water has cease to come out from the drain pipe but it’s giving purified water of tds 34 from input water of tds 113.

John Woodard, Master Water Specialist

Hi Michael!

From the information you’ve provided, we can’t identify with certainty what the root of your problem is. We’ll be reaching out to you personally to help you with your RO system.


Michael

Hi, I have the exact same problem as Grant, and followed the flow rate test. Our system is older, a microline system with 14 gpd filters. We had around 8 gpd. What is the next step in solving this problem? Replacing the R.O. filter?


John Woodard, Master Water Specialist

Hi Grant,

RO constant run to drain typically means pressure is not building enough in the tank to actuate the ASO valve. Depending on your water conditions, an older membrane may not be making water very fast so as pressure builds in the tank as it fills, it becomes so slow the ASO never sees enough tank pressure to close. (2/3 of what the feed pressure is)

Do a flow rate test to see what the membrane is producing. With tank valve off, lift faucet handle and let it run for a few minutes. Then collect the slow trickle in a measuring cup. A 35 GPD membrane should produce 2-3 ounces and a 50 gpd should produce 3-4 ounces in 60 seconds. This can vary due to feed pressure and water temperature. It will give us an idea of what the membrane is doing. Also empty the tank completely and test air charge. Empty tank should be close to 7psi.

While testing make sure any remote connections are closed like a run to the fridge / ice maker.

Let us know how that goes.


Grant

Found that my drain line was running continously. First thing in the morning, poured some water for coffee and then went and shut off tank feed. Drain line continued to run. Checked the check valve by turning off the main feed and opening up the tank valves – no water in th drain line. Put in a new ASO – drain continued to run, even with tank valve shut off. Interestingly, I shut off the main feed for a minute (drain line stopped flowing) and then turned it back on again, and the drain line did not run. Once I got some water out of the tap though, the drain began to run again and won’t stop. Pre-filter and carbon filters changed about 3 months ago – membrane hasn’t been changed for a few years. Would that have anything to do with what is happening? Main feed is coming from a cistern – pressure is set between 35 and 55 psi if that helps. Any suggestions?


John Woodard, Master Water Specialist

Hi Heidar,

There are a variety of possible explanations for this issue. In order to best help you, we’ll need some more information. What type of filtration system do you have, and what specific filters are you referring to? It will also be helpful to know what the water source is. Is it city / municipally treated or from a private well? Let us know so we can help you figure out the issue.


Heidar
Hi, In the past whenever I replaced the filters, the flow rate was very fast and I could fill out 5 gallon in a few minutes. Now, after changing the filters, the flow rate is initially moderate but I can barely fill out a three gallon. After a month or two them water flow becomes very slow.

John Woodard, Master Water Specialist

Hi Tim,

A loud vibration noise can result from a couple of issues. The most typical is air trapped in the ASO (auto shut off). Sometimes it helps to make sure the tank is empty (when empty, check for air pre-charge at 5-7 psi) and the tank valve closed and let the system run with the faucet open for 20 minutes or so to allow the air to work its way out. Once spits and sputters have stopped, slowly open the empty tank valve and allow it to fill and dump at least two tanks. Should be good to go.

If vibration still occurs with the tank off and the faucet open, the the ASO valve is probably not the problem. Is noise coming from air-gap hole in faucet body? This would indicate water velocity through the drain line is way too high, meaning the flow restrictor is either missing or not functioning. The flow restrictor, depending on the make of the system, is usually an insert in the end of the drain tube that connects to the RO itself.

I hope that helps. Let us know if you have additional questions!


Tim Mulcahy
I replaced all 5 filters on my under sink RO system. Now it makes a load vibration sound when in use. I followed instructions on how to bleed the lines and didn’t work. Then I replaced the shut off valve. Still no help. I’m stumped and can’t find a solution. Any ideas ? Thanks

Demille Vantigo

Leaky quick connects can create problems if the tubing has been yanked apart several times. If it helps anyone, simple explanation here: https://youtu.be/A8j9dO-2iNE


John Woodard, Master Water Specialist

Hi Kit,

The iron curtain oxidizes dissolved iron, which converts it to solid particles. These particles get captured in the filter media. If the water softener follows the iron curtain, then any oxidized iron that bleeds through (didn’t get caught by the iron curtain) will pass right through and clog the RO.

This is what I would look for first. If you inspect the RO system’s drain line (disconnect it from the sink drain) and notice that it’s orange inside, then that iron clogging the RO is the problem. I hope that helps.